High-flow nasal cannula oxygenation for awake craniotomy in patients with obesity: looking beyond oxygenation

Article information

Anesth Pain Med. 2022;17(2):245-245
Publication date (electronic) : 2022 April 29
doi : https://doi.org/10.17085/apm.22153
1Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Raipur, India
2Department of Anesthesiology and Intensive Care, University Hospital of Waterford, Waterford, Ireland
3Intensive Care Unit, Hospital Morales Meseguer, Murcia, Spain
4Editor in Chief, Journal of Neuroanaesthesiology and Critical Care, Noida, India
Corresponding Author: Habib Md Reazaul Karim, M.D., DNB, IDCCM, FNIV Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, 201, Suryodaya Colony, Tatibandh, Raipur, India. Tel: 91-9612372585, E-mail: drhabibkarim@aiimsraipur.edu.in
Former affiliation: Parmod Kumar Bithal: Professor and Head, Department of Neuroanaesthesiology and Critical Care, All India Institute of Medical Sciences, New Delhi, India
Received 2022 February 27; Accepted 2022 April 7.

TO THE EDITOR: We read with interest the use of high-flow nasal cannula (HFNC) oxygenation to prevent sedation-induced hypoxia in patients undergoing awake craniotomy. The authors report interesting observations, particularly the case of obstructive sleep apnea (OSA) [1]. While the findings could be applied in future clinical practice, some methodological aspects are worth a discussion.

The authors used the oxygen reserve index (ORI) to predict desaturation early and found it better compared to peripheral oxyhemoglobin saturation. While monitoring for oxygenation is vital in procedural sedation, the ventilation status is equally critical in patients with neurosurgical disorders as it can impact carbon dioxide removal and, subsequently, intracranial blood flow and pressure. Although end-tidal carbon dioxide monitoring can provide information regarding ventilation, it has disadvantages of technical difficulty and a high error rate in patients receiving HFNC oxygenation [2]; the recent technology of transcutaneous carbon dioxide monitoring might be an alternative in the future [3]. Sedation with propofol and remifentanil can lead to severe hypoventilation and even airway compromise, particularly in patients with OSA. The authors managed to perform intraoperative sedation well with targeted bi-spectral index values. Nonetheless, airway collapse is common with the drugs used, i.e., propofol and remifentanil infusion after midazolam premedication. Patients with obesity and OSA often require high pressure to prevent upper airway collapse as their pharyngeal critical closing pressure (Pcrit) is higher [4]. While HNFC oxygenation exerts a continuous positive airway pressure-like effect, it is flow-dependent. In such a scenario, the flow of 15–30 L/min applied by the authors might not be sufficient to overcome the Pcrit. Therefore, the methods used for the assessment of ventilation and prevention of hypoventilation should be outlined.

Airway management is crucial during awake craniotomy, as is sedation. HFNC oxygenation plays a role in preventing hypoxemia [1,5]. We congratulate the authors for their compelling case and highlighting the role of ORI in early detection of impending desaturation during HFNC oxygenation. However, we feel that dexmedetomidine, known to provide sedation and analgesia without causing respiratory depression, would be a better agent in patients with OSA and welcome additional thoughts and opinions to guide decision-making.

Notes

FUNDING

None.

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

AUTHOR CONTRIBUTIONS

Conceptualization: Habib Md Reazaul Karim, Pradipta Bhakta, Antonio M Esquinas. Data curation: Habib Md Reazaul Karim, Pradipta Bhakta, Antonio M Esquinas, Parmod Kumar Bithal. Formal analysis: Habib Md Reazaul Karim, Pradipta Bhakta, Antonio M Esquinas, Parmod Kumar Bithal. Writing - original draft: Habib Md Reazaul Karim, Antonio M Esquinas. Writing - review & editing: Habib Md Reazaul Karim, Pradipta Bhakta, Parmod Kumar Bithal. Resources: Habib Md Reazaul Karim, Pradipta Bhakta, Parmod Kumar Bithal.

References

1. Gook J, Kwon JH, Kim K, Choi JW, Chung IS, Lee J. Awake craniotomy using a high-flow nasal cannula with oxygen reserve index monitoring - A report of two cases. Anesth Pain Med (Seoul) 2021;16:338–43.
2. Ebert TJ, Novalija J, Uhrich TD, Barney JA. The effectiveness of oxygen delivery and reliability of carbon dioxide waveforms: a crossover comparison of 4 nasal cannulae. Anesth Analg 2015;120:342–8.
3. Reese A, Deruyter M. High flow nasal oxygen therapy and transcutaneous carbon dioxide monitoring for awake craniotomy. Turk J Anaesthesiol Reanim 2018;46:326–7.
4. Genta PR, Schorr F, Eckert DJ, Gebrim E, Kayamori F, Moriya HT, et al. Upper airway collapsibility is associated with obesity and hyoid position. Sleep 2014;37:1673–8.
5. Yi P, Li Q, Yang Z, Cao L, Hu X, Gu H. High-flow nasal cannula improves clinical efficacy of airway management in patients undergoing awake craniotomy. BMC Anesthesiol 2020;20:156.

Article information Continued