Anesth Pain Med Search

CLOSE


Cardiothoracic and Vascular Anesthesia
Anesthesia and Pain Medicine 2013;8(1):1-8.
Published online January 31, 2013.
Monitoring for fluid management: dynamic guides and fluid responsiveness
Young Lan Kwak
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Korea. ylkwak@yuhs.ac
Abstract
In the heart, ventricular end diastolic volume (EDV) before ejection (preload) is directly related to the amount of stroke volume. Generally, the filling pressures such as central venous pressure or pulmonary artery occlusion pressure are used as an indirect indicator of preload. Since cardiac compliance dose change, however, the filling pressure may not be an accurate indicator of the cardiac preload. As substitutes, volumetric parameters like right ventricular EDV or global end diastolic volume were developed and reported to be superior to the filling pressure in the assessment of preload. Preload responding volume resuscitation, however, is different according to the patient's condition. Whether any improvement is to be expected from volume resuscitation depends on whether the heart operates on the steep portion in its function curve. Under mechanical ventilation, because of the influence of positive pressure on vena caval and pulmonary venous return, arterial blood pressure and pulse pressure are maximum during inspiration and minimum a few heart-beats later, i.e., during the expiratory period. These periodic changes become prominent under the hypovolemic condition. Recently, various monitors continuously measuring pulse pressure variation (PPV) or stroke volume variation (SVV) using analysis of arterial wave is widely used as a dynamic guidance for volume resuscitation in mechanically ventilated patients. The ability of those variables to predict fluid responsiveness is better than those of filling pressure or EDV. Thus, PPV and SVV could be beneficially used to guide fluid therapy, while the safety limit of fluid therapy should be based on filling pressure.
Key Words: Fluid responsiveness, Monitoring, Pulse pressure variation, Stroke volume variation
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,254 View
  • 19 Download
Related articles in Anesth Pain Med


ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: apm@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next